Probe for measurement of metal surface temperature, air temperature, relative air humidity, temperature of dew point and calculation of the difference between metal surface temperature and temperature of dew point (inspection of conditions during painting of metal products).

The ΔT parameter represents the difference between the metal surface temperature and the dew point temperature. If ΔT is less than 3–4 °C, painting works is not permitted, as condensation will form on the surface.

Data shown on device display when THDC probe is connected

Features

  • Measurement of all relevant environmental and surface parameters for painting works.
  • Automatic calculation of the ΔT parameter.
  • Convenient probe design enabling temperature measurement on metal surfaces, including hard-to-reach areas.
  • High measurement speed.

Basic technical characteristics

Technical data THDC
measurement range: air temperature: from -10 to +40 °С
metal surface temperature: from -40 to +85 °С
relative air humidity: from 5 to 90 %
measurement accuracy: air temperature: ≤ ±3 °C
relative air humidity: ≤ ±3 %
size THD probe: Ø16,5×32 mm
TC probe: Ø18×86 mm