NDT1 KRAFT s.r.o.
NDT1 KRAFT s.r.o.

ED-1mm, ED-1mm-REddy Current Flaw Detectors

ED-1mm, ED-1mm-REddy Current Flaw Detectors

ISO
ISO 15548-2, ISO 17643

The ED-1mm and ED-1mm-R are wireless eddy current flaw detectors with a highly localized 1 mm sensing element for detection and depth measurement of small and short surface cracks. Their small inspection area makes them particularly suitable for precise local testing, small components and areas where high spatial resolution is required.

Description

The ED-1mm series is designed for highly localized eddy current inspection and depth measurement of short surface-breaking defects on metallic components made of ferromagnetic steels and cast irons, aluminum and titanium alloys, and low-magnetic stainless steels. The 1 mm sensing element provides a small area of influence, allowing the detector to identify defects in restricted inspection zones and distinguish closely located surface features more effectively than larger-sensing-element models.

The devices are particularly suitable for inspection of small parts, localized areas and components where detection of short cracks is the primary requirement. The defect depth measurement range is 0.2–2 mm, while defects as short as 2 mm can be detected.

Features

  • Wireless eddy current flaw detector for surface crack detection and depth measurement
  • Detection and depth measurement of surface-breaking defects
  • Highly localized 1 mm sensing element
  • Detection of short and small surface defects
  • Minimum detectable defect length from 2 mm
  • Minimum detectable defect depth down to 0.05 mm for steel
  • Defect depth measurement from 0.2 to 2 mm
  • Optimized for applications where high spatial resolution is required
  • Inspection through dielectric coatings and surface contamination
  • Suitable for ferromagnetic steels, cast iron, aluminum and titanium alloys, and stainless steels
  • Material selection for adapting the device to the inspected object
  • Direct display of crack depth
  • Audible and vibration alarms when the defect threshold is exceeded
  • Bluetooth connection to smartphones and tablets
  • Dedicated application providing the functionality of an amplitude-phase eddy current flaw detector
  • Compact design for field inspection
  • Impact-resistant ergonomic housing
  • Ceramic protective cap
  • Extended operating temperature range

Basic technical characteristics

Parameter ED-1mm ED-1mm-R
Stand-alone operation or operation with display device
Sensitive element type absolute
Sensitive coils diameter, mm 1
Radius of influence area, mm 2.5
Materials parameters of tested object:
steel μ ≥ 10 rel. units; σ > 0.5 MS/m
aluminum μ ≈ 1 rel. unit; 3.5 < σ < 60 MS/m
titanium μ ≈ 1 rel. unit; 0.5 < σ < 5 MS/m
stainless steel μ < 10 rel. units; 0.5 < σ < 5 MS/m
Excitation frequency, MHz:
steel profile 7.5
aluminum profile 5
titanium profile 10
stainless steel profile 7.5
Minimum detectable defect depth, mm:
steel profile 0.05
aluminum profile 0.15
titanium profile
stainless steel profile
Minimum detectable defect length, mm 2
Defect depth measurement resolution, mm 0.01
Minimum defect length for depth measurement, mm 8
Defect depth measurement range, mm 0.2-2
Maximum permissible error of defect depth measurement ± (0.15Z + 0.1) mm, where Z is the actual defect depth
Maximum dielectric coating thickness, mm:
for defect depth measurement with specified accuracy 0.3
for defect detection 0.5
Maximum surface roughness Rz, µm 20
High-pass filter cutoff frequency during scanning, Hz 5
Scanning speed for defect detection, mm/s 3 to 150
Scanning speed for defect depth measurement, mm/s up to 15
Overall dimensions, max., mm 156 × 30 × 30 180 × 30 × 30
Weight, max., kg 0.1
Indication colour IPS display, audible alarm, vibration alarm
Display size 0.96″
Display resolution 80 × 160
Operating conditions:
ambient temperature -30 to +50 °C
relative humidity 40 to 80 %
Degree of protection IP67
Continuous operating time from built-in Li-ion battery ≥ 12 h
Operation with display device
Excitation frequency, MHz 1; 1.5; 2; 3; 4; 5; 6; 7.5; 10
Pre-amplification, dB 6–36, step 6
X/Y gain, dB 0–40, step 0.1
Phase, ° 0–359.9, step 0.1
High-pass filter, Hz 0–10, step 1
Low-pass filter, Hz 10–240, step 1
Alarm types:
complex plane display gate, double gate, sector, double sector
time-base display threshold, mirrored threshold
Overall dimensions of display device, max., mm 180 × 90 × 25
Weight of display device, max., kg 0.5
Display size 6.5″
Display resolution 2400 × 1800
Operating conditions:
ambient temperature -30 to +50 °C
relative humidity 40 to 80 %
Degree of protection IP68
Continuous operating time from built-in Li-ion battery ≥ 30 h

Delivery set

  • Eddy current flaw detector
  • Display device (rugged smartphone with pre-installed software)
  • Charging device with USB-C to USB-C cable
  • Reference defect specimens MMD-110-Fe, MMD-110-Al, MMD-110-Ti
  • Operating manual
  • Storage and carrying case










    I agree with the privacy policy

    Manage cookies
    We use cookies to provide the best site experience.
    Accept All