K6-C

The K6-C multifunctional coating thickness gauge is a high-precision device designed for accurate measuring geometric and environmental parameters: coating thickness, groove depth, surface roughness, air humidity, air and metal surface temperature, dew point temperature, TΔ parameter.
Description
The K6-C coating thickness gauge is a high-precision device designed for accurate thickness measurement of coatings on steel and non-ferrous metals. This coating thickness meter is widely used in industrial inspection to test paint, galvanic, and dielectric coatings, ensuring product quality.
Measuring the thickness of:
— galvanic (zinc, chromium, nickel, cadmium, silver, tin, and other) coatings on steel products;
— galvanic (zinc, chromium, nickel, cadmium, silver, tin, and other) coatings on non-ferrous metal products;
— paint, enamel, powder, mastic, and other dielectric coatings on steel products;
— anodic oxide, phosphate, and other dielectric coatings on ferrous and non-ferrous metals;
— special dielectric and metallic thick-layer coatings, galvanic coatings;
— coatings on the inner surfaces of pipes and cylindrical products;
— copper foil on printed circuit boards;
— sheets of conductive non-ferrous metals and galvanic coatings on dielectric products; — two-layer coatings;
— concrete protective layers and determination of reinforcement position in concrete;
— wall thickness of large fiberglass and carbon fiber reinforced plastic products during manufacturing and shipping with single- and double-sided access;
— groove depth measurement and surface roughness assessment after sandblasting or abrasive treatment;
— climatic conditions monitoring (air humidity, air and metal surface temperature, dew point temperature, and determination of TΔ).
Features
— colour TFT display with 2.4” diagonal;
— built-in lithium-ion battery;
— impact-resistant, ergonomic housing with rubberized corners;
— keyboard with function keys that adapt to the device operating mode, featuring a user-friendly and intuitive interface;
— additional device modes and settings;
— an expanded set of wear-resistant, ergonomic, compact sensors;
— support for sensors with multiple calibration characteristics (up to 6 for PH3 series sensors, up to 4 for NF-G sensors, up to 2 for FG sensors).
Basic technical characteristics
| Parameter | K6-C | Units |
|---|---|---|
| the range of thickness control (depends on connected probe) | 0.5 µm…120 mm | |
| number of probes | unlimited (according to customer’s choice) | |
| temperature range: | for device: -10…+40 °C (-30 °C for frost-resistant version) | |
| for probes: -40…+50 °C (up to +350 °C for high temperature probes) | ||
| calibration methods: | additive one-point | |
| two-point | ||
| one-point with automatic multiplicative correction | ||
| power supply | built-in Li-Ion battery in 3.7-4.2 V, 1500-1700 mAh | |
| continuous operation time, min. | 12 | h |
| connectivity with PC | USB 2.0 channel | |
| overall dimensions | 60×125×25 | mm |
| weight of electronic unit | 120 | g |
| charging time | 4 | h |
| guarantee period: | measuring unit — 3 years | |
| probes — 2 years | ||
Delivery set

- Measuring unit
- Probes (quantity and modification according to customer’s selection)
- Charger unit
- Set of coating thickness reference specimens
- Base reference samples (based on selected converters)
- Mini-USB to USB Type A cable for connection with PC
- Operating manual
- Shock-resistant case
Probes
Probes for the Magneto-Inductive measurement method
The F probes for K6-C contain one calibration characteristic for measuring coating thickness on ferromagnetic bases.
Probes for the Eddy-Current measurement method
Probes NF for K6-C contain one calibration characteristics for coatings thickness measurement on non-ferromagnetic bases.
Probes for the Eddy-Current phase measurement method
Probes PH for K6-C contain one “coating/base” characteristics.
Specialized probes
Video materials
Description of K6-C Thickness Gauge
K6-C - Measurements and Calibration
K6-C - Scanning Mode
Related products
-

THDC
Probe for measurement of metal surface temperature, air temperature, relative air humidity, temperature of dew point and calculation of the difference between metal surface temperature and temperature of dew point...
Probes for measuring environmental parameters: air humidity, air and metal surface temperature, dew point temperature, TΔ parameter.
-

F4
F4 is a probe designed for measuring the thickness of non-ferromagnetic (bitumen, mastic, plastic, heat-resistant, etc.) coatings on ferromagnetic parts with medium to high surface roughness. Features: Probe with a...
F series Magneto-Inductive probes for K5-C and K6-C thickness gauges.
-

NF1
NF1 is a probe designed for measuring the thickness of dielectric (anode oxide, paint, lacquer, powder, etc.) coatings on current-conducting non-ferromagnetic parts.
NF series Eddy-Current probes for K5-C and K6-C thickness gauges.
-

NF0
NF0 is a probe designed for measuring the thickness of dielectric (anode oxide, paint, lacquer, powder, etc.) coatings on current-conducting non-ferromagnetic parts.
NF series Eddy-Current probes for K5-C and K6-C thickness gauges.