Dual element probe 10A6
Description
Purpose
Measurement of thickness of pipes, curved areas of containers with small radius.
Particulars
Utilization of new synthetic materials provides low wear and good interfacing with rough surfaces.
Basic Technical Characteristics
| Technical data | Dual element probe 10A6 | Units |
|---|---|---|
| operation frequency | 10 | MHz |
| thickness range (for steel) | from 0.6 to 20 | mm |
| dimensions of contact surface | Ø6 | mm |
| overall dimensions | Ø14 x 26 | mm |
| operating temperature range | from -10 to +60 | °C |