MK4-C_1
MK4-C_2

Product Description

Purpose
Small-sized device for operative coating thickness measurements of paint, lacquer, galvanic, powder bitumen and other coatings on substrates from ferrous and non-ferrous materials with increased temperature range.

Features
— colour OLED display with 1.7’’ diagonal, large digits on display;
— device can be delivered with integrated combined small-sized probe for measuring coating thickness on substrates from ferrous and non-ferrous materials;
— increased temperature range up to -30°C;
— possibility of tolerance mode measurement, measuring with averaging;
— device can be delivered with integrated probe or with built-in probe on cable.

Basic technical characteristics
— accuracy: in range T = 0…500 µm ±(0,02T+1) µm; in range T = 500…Tmax ±0,02T µm;
— temperature range: for device: -30 °C…+40 °C; for probe: -40 °C…+ 50 °C;
— power-supply: built-in Li-Ion rechargeable battery, 3,7 – 4,2 V, 700 mAh;
— overall dimensions: 120 × 45 × 20 mm;
— weight: 130 g;
— operating time: min 8 h.

Delivery set
The device can be completed with measuring probe, set of coating reference specimens (calibration foils), sample of metal substrate, charging unit, operating manual, container for storage and transportation (case or bag).

 


Combined Magneto-Inductive and Eddy Current Parametric measurement method probe

FNF
Probe for thickness measurement of paint, powder, plastic, enamel and other non-ferrous dielectric
coatings on conductive ferrous and non-ferrous materials.

FNF

Technical features

  • measurement range, T: 0-1000 μm (1 mm);
  • measurement accuracy, μm: ± (0,015T+1);
  • diameter of test area, mm: 6;
  • minimum diameter of substrate, mm, Øconvex/Øconcave: 4/12;
  • dimensions, mm: Ø21×90.

 

 Probes for the Magneto-Inductive measurement method

Probes F for MK4-C contain one calibration characteristics for coatings thickness measurement on ferromagnetic bases.

F1
Probe for measuring of galvanic (zinc, chrome, cadmium, etc.) and dielectric (plastic, paint, etc.) coatings upon small-size articles made of ferromagnetic materials.

F1_1
Technical features

  • measurement range, T: 0-300 µm (0,3mm);
  • measurement accuracy: ±(0,02T+1) µm;
  • diameter of test area, Øm, mm: 4 ;
  • minimum diameter of substrate, mm, Øconc ( Øconv): 4,5 (1);
  • size, mm: Ø9×65.

Particulars
Wear-resistant probe with spring-loaded measuring system for control of galvanic coatings, provides complete tuning out from influence of coating ’ s electric conductivity.


F2
Probe for dielectric (paint, powder, anode oxide, etc.) and current-conducting non-ferromagnetic (zinc, chrome, etc.) coatings upon articles made of ferromagnetic materials within the range of up to 2 mm.

F2
Technical features

  • measurement range, T: 0-2000 µm (2mm);
  • measurement accuracy: ±0,02T µm;
  • diameter of test area, Øm, mm: 6 ;
  • minimum diameter of substrate, mm, Øconc ( Øconv): 9,0 (1,5);
  • size, mm: Ø19×83.

Particulars 
Probe with  spring-loaded measuring system. Using of hard-metal material for the tip allows to exclude its wear-out.


F3
Probe for dielectric (paint, powder, anode oxide, etc.) and current-conducting non-ferromagnetic (zinc, chrome, etc.) coatings upon articles made of ferromagnetic materials within the range of up to 5 mm.

F3
Technical features

  • measurement range, T: 0-6000 µm (6 mm);
  • measurement accuracy: ±0,02T µm;
  • diameter of test area, Øm, mm: 8 ;
  • minimum diameter of substrate, mm, Øconc ( Øconv): 10,5 (2,5);
  • size, mm: Ø19×83.

Particulars 
Probe with  spring-loaded measuring system for thick coatings.


F4
Thickness measurement of bitumen, plastic, foil, heat resistant and other non-ferrous coatings (including special purpose coatings) on substrates from steel with average and large surface roughness.

F4

Technical features

  • measurement range, T: 0-8 mm;
  • accuracy in measurement range: 0–6 mm: ≤±(0,015T +0,01) mm; 6–8 mm: ≤±0,02T;
  • minimum diameter of substrate, outer diameter/inner diameter, mm : 5/18,5;
  • diameter of test area Ø, mm: 12;
  • dimensions, mm: Ø15×49.

F5
Thickness measurement of bitumen, plastic, foil, heat resistant and other non-ferrous coatings (including special purpose coatings) on substrates from steel with average and large surface roughness.

F5

Technical features

  • measurement range, T: 0-10 mm;
  • accuracy in measurement range: 0-10 mm 1–8 mm: ≤±(0,015T+0,01) mm; 8–10 mm: ≤±0,02T;
  • minimum diameter of substrate, outer diameter/inner diameter, mm : 7/57;
  • diameter of test area Ø, mm: 17;
  • dimensions, mm:  Ø23×58.

Probes for the Eddy-Current measurement method

Probes NF for MK4-C contain one calibration characteristics for coatings thickness measurement on non-ferromagnetic bases.

NF0
Probe for measuring of dielectric (paint, anode oxide, powder, etc) and current-conducting non-ferromagnetic (tin, zinc, etc.) coatings upon articles made of current-conducting non-ferromagnetic materials within the range of up to 500  µm.

NF0
Technical features:

  • measurement range, T: 0-500 µm (0,5 mm);
  • measurement accuracy: ±(0,02T+1) µm;
  • diameter of test area, mm: 1,5 ;
  • minimum diameter of substrate, mm, Øconc ( Øconv): 2/12
  • size, mm: Ø19×103.

Particulars
Probes with  spring-loaded measuring system. Utilization of modern durable materials  provides high strength and wear resistance of probe.


NF1
F2
Probe for measuring of thickness of dielectric (paint, anode oxide, powder, etc) and current-conducting non-ferromagnetic (tin, zinc, etc.) coatings upon articles made of current-conducting non-ferromagnetic materials within the range of up to 2000  µm,
Technical features

  • measurement range, T: 0-2000 µm (2 mm);
  • measurement accuracy: ±0,02T µm;
  • diameter of test area, mm: 4,7 ;
  • minimum diameter of substrate, mm, Øconc ( Øconv): 4/12
  • size, mm: Ø19×83.

Particulars
Probes with  spring-loaded measuring system. Utilization of modern materials  provides high strength and wear resistance of probe.


NF2

Technical features

  • measurement range, T: 0-12000 µm (12 mm);
  • measurement accuracy: ±0,02T µm;
  • diameter of test area, mm: 20 ;
  • minimum radius of base, mm, Øconc ( Øconv): 12 (5);
  • size, mm: Ø19×83.

NF2 probe

NF3

  • measurement range, T: 0-30000 µm (30 mm);
  • measurement accuracy: ±0,02T µm;
  • diameter of test area, mm: 40 ;
  • minimum radius of base, mm, Øconc ( Øconv): 45 (15);
  • size, mm: Ø23×87.

NF3 probe

Reviews

There are no reviews yet.

Be the first to review “MK4-C”